Stratford, the Royal Docks, Canning Town and East Ham
Newham adopted its new Local Plan on 2nd November 2026, ending the LLDC plan's role in the borough, defining tall buildings as 21 metres or more and naming 22 Tall Building Zones. We write fire strategies for Stratford towers, Royal Docks schemes and the borough's mills, theatres and high street shops.
- Reply
- Same-day reply
- Fee
- Fixed, agreed before we start
- Signed off by
- A Chartered Engineer (CEng)
- Coverage
- In-house engineering, UK wide
- Scroll
Overview
Fire strategy for Newham buildings
Newham submitted the Our Newham Local Plan on 18th July 2025 and held hearings in December 2025 and February 2026. The Inspector's Report of 18th August 2026 found it sound subject to main modifications. Adoption replaced the Newham Local Plan 2018 and withdrew the LLDC Local Plan (2020) inside Newham, while LLDC and Olympic Delivery Authority records are still being added to the council's register.
Policy D4 counts a building as tall at or over 21 metres, measured from the ground to the top of the highest storey. The tallest clusters are consolidated in TBZ13 Canning Town, TBZ15 West Ham Station and TBZ19 Stratford Central. Albert Island, King George V/Pier Parade and Excel West are among the zones the plan calls constrained by airport proximity, where height transitions are managed.
The Royal Docks and Beckton Riverside framework, adopted by the Mayor of London in May 2023, identifies potential for 36,300 homes and 55,700 jobs and sets the context for a proposed DLR extension to Thamesmead. Newham has nine conservation areas, from Three Mills and Sugar House Lane to the Woodgrange Estate. Article 4 directions apply in Durham Road, Romford Road and Woodgrange Road.
Who decides
Who approves a fire strategy in Newham
- Planning
- London Borough of Newham (official source, opens in a new tab)
- Has decided applications on its part of the old LLDC area since 1st December 2024 and now does so under its 2026 Local Plan.
- Building control
- Newham Building Control (official source, opens in a new tab)
- The council's own team approves regulations work in the borough. Higher-risk buildings sit with the Building Safety Regulator rather than the council.
- Fire station
- Stratford Fire Station (official source, opens in a new tab)
- At 117 Romford Road. East Ham and Plaistow complete the brigade's list for Newham.
- Local plan
- Our Newham Local Plan (official source, opens in a new tab)
- Adopted on 2nd November 2026, with Policy D4 setting the Tall Building Zones.
Local issues
What a Newham fire strategy has to deal with.
Battery charging and storage
Paragraph T3.5 of the new plan asks applicants providing e-bike and mobility scooter charging to liaise with Building Control and the London Fire Brigade. Schemes pairing battery energy storage with on-site renewables are encouraged to discuss them with LFB. Charging rooms and battery stores need their position, separation and ventilation fixed before the layout is.
A car park fire at Westfield
On 13th September 2025 around 10 vehicles were destroyed on the second floor of car park C at Westfield on Montfichet Road and the shopping centre was evacuated. Ten fire engines and around 70 firefighters attended. A car park joined to a shopping centre needs its ventilation, separation and the centre's evacuation planned as one.
Flats above East Ham shops
A fire on High Street North on 29th May 2025 destroyed the first floor of a shop with dwellings above, with 11 people evacuated by a 20 engine attendance. Homes over a shop need fire resisting construction between the two uses and a way out that does not pass through the shop.
Grade I mill at Three Mills
The Tide Mill on Three Mills Lane, known as the House Mill, is listed grade I. Abbey Mills Pumping Station on Abbey Lane is grade II*. Any new use of buildings like these has to add escape and detection with as little loss of historic fabric as possible.
Building types
The building types we see in Newham
- Fire Strategy for Mixed Use Developments
East Bank in Queen Elizabeth Olympic Park, with the BBC, Sadler's Wells, London College of Fashion UAL, UCL and the V&A
- Fire Strategy for High-Rise Residential Buildings
Tall Building Zones at Canning Town, West Ham Station and Stratford Central
- Fire Strategy for Heritage Buildings and Conversions
The House Mill, Abbey Mills Pumping Station and the grade II* Theatre Royal on Salway Road
- Fire Strategy for Car Parks and Basements
The multi-storey car park at Westfield on Montfichet Road in Stratford
What we deliver
Fire strategy services in Newham.

Planning Fire Statements and Gateway 1
Gateway 1 and London Plan D12, UK wide
Read more
Fire Engineering
Performance based design, in-house, UK wide
Read more
Smoke Control and Evacuation Modelling
Fire engineering in-house, UK wide
Read more
Gateway 2 and Gateway 3 Support
Higher-risk buildings, BSR submissions, UK wide
Read moreCommon questions
Fire strategy questions in Newham, answered.
Cannot see your question? Get in touch and we will answer it directly.
All fire strategy questionsThe council says the LLDC Local Plan (2020) and LLDC guidance stopped applying in Newham once its own Local Plan was adopted on 2nd November 2026.
Guides
Guides worth reading first.
More in London
All locationsFire strategy in Newham
Tell us about the building
Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.
- 01Written in-house by the engineer who will defend it to the approver
- 02Approved Document B, BS 9999, BS 9991 and BS 7974
- 03Building Control and fire authority engagement handled for you
- 04Projects of every size, across the UK
Request a quote
Same-day reply