Mixed use schemes put a sleeping risk above a commercial one, often sharing a core, a basement and a fire alarm. The strategy has to make BS 9991 and BS 9999 coexist in one building and keep every use safe from the others.

Reply
Same-day reply
Fee
Fixed, agreed before we start
Written to
BS 9991:2024, BS 9999:2017, Approved Document B Volumes 1 and 2
Signed off by
A Chartered Engineer (CEng)
Scroll

What makes this sector different

What a fire strategy for mixed use buildings has to answer.

01

Two codes, one building

Residential floors to BS 9991 and commercial floors to BS 9999, with a coherent approach where they meet.

02

Separation

Compartmentation between uses, the podium deck and the services that cross it.

03

Shared cores and basements

Escape and firefighting provision shared by occupants with very different needs.

04

Management

Several Responsible Persons and Accountable Persons who have to cooperate.

Evacuation strategy

How evacuation works in a mixed use building

A mixed use building usually runs two evacuation strategies at once. The flats stay put while the shops, offices or leisure units below evacuate simultaneously. That only works if a fire in the commercial part cannot threaten the flats. Compartment floors and walls between the uses, separate escape routes and separate alarm systems are what make it possible.

The detail that causes trouble is where the uses touch. Shared stairs, a common basement car park, service risers that pass through the podium and plant that serves both parts all need a clear rule in the strategy. We state for each one whether it is shared or separated and what protects it.

Our approach

How we write a fire strategy for mixed use buildings.

We write one strategy for the whole scheme with a clear statement of how the uses are separated, where the strategy changes code and which measures are shared. Where the massing or the core arrangement defeats the guidance we engineer the justification in-house.

Typical deliverables

  • Whole scheme fire strategy and plans
  • Interface schedule between uses
  • Gateway submissions where applicable
  • Management responsibilities matrix

Standards and guidance

Fire safety guidance for mixed use buildings

BS 9991:2024
Covers the residential floors and sets the conditions under which a stair serving flats may also serve other uses.
BS 9999:2017
Covers the commercial floors using risk profiles based on who occupies the space and how fast a fire could grow.
Approved Document B Volumes 1 and 2 (official source, opens in a new tab)
Volume 1 covers dwellings and Volume 2 covers everything else. A mixed use scheme has to satisfy both.
Building Safety Act 2022 where the residential part is higher-risk (official source, opens in a new tab)
Applies where the building contains at least two residential units and meets the height test. That brings the scheme into the gateway process unless a part qualifies as an independent section.

Common questions

Fire strategy questions on mixed use buildings, answered.

Cannot see your question? Get in touch and we will answer it directly.

All fire strategy questions

If it is at least 18 metres or seven storeys and contains at least two residential units, yes, the whole building is in scope for the gateways and, in occupation, the residential parts and the common parts fall under the Accountable Person duties.

Guides

Guides for mixed use buildings.

Other sectors

All sectors

Fire strategy for mixed use buildings

Tell us about the building

Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK