Shops, shopping centres, cinemas and gyms

Retail and leisure buildings hold large numbers of people who do not know the building. The strategy has to deliver exit capacity, manageable compartment sizes and smoke control for spaces designed to be open.

Reply
Same-day reply
Fee
Fixed, agreed before we start
Written to
BS 9999:2017, Approved Document B Volume 2, BS 5588-10 principles for shopping complexes
Signed off by
A Chartered Engineer (CEng)
Scroll

What makes this sector different

What a fire strategy for retail and leisure buildings has to answer.

01

Occupancy

Floor space factors and exit capacity for buildings whose whole point is to fill up.

02

Large compartments

Retail wants big floorplates. Sprinklers, smoke control and engineered analysis make them possible.

03

Assembly spaces

Cinemas, gyms and food halls bring assembly use with its own guidance.

04

Tenant turnover

Shopping centres need a landlord strategy that each unit's fit out can be checked against.

Evacuation strategy

How evacuation works in shops and leisure venues

Shops and leisure venues evacuate simultaneously. The public do not know the building and tend to leave by the way they came in. The strategy cannot rely on signs alone. Exits are distributed to stop the main entrance being the only route people will choose and exit widths are sized from the number of people the floor area can hold.

That number comes from floor space factors. A supermarket sales floor, a bar, a gym and a cinema each put a different number of people on the same area. A change of tenant can therefore change the exit capacity a unit needs. In shopping centres the malls double as escape routes and smoke reservoirs, which is why they need their own smoke control design.

Our approach

How we write a fire strategy for retail and leisure buildings.

We write strategies that let retail and leisure buildings stay open and flexible, using BS 9999 risk profiles and, where the floorplate demands it, engineered justification for compartment size and smoke control.

Typical deliverables

  • Fire strategy report and plans
  • Occupancy and exit capacity schedule
  • Landlord strategy and unit fit out rules
  • Smoke control design intent

Standards and guidance

Fire safety guidance for retail and leisure buildings

BS 9999:2017
Sets exit widths, travel distances and compartment sizes from the risk profile of each space, with allowances for sprinklers.
Approved Document B Volume 2 (official source, opens in a new tab)
Gives the floor space factors used to calculate occupancy and limits a shop compartment without sprinklers to 2,000 square metres.
BS 5588-10 principles for shopping complexes
The withdrawn code for shopping complexes. Its principles for malls and smoke control are still widely referred to alongside BS 9999.
Fire Safety Order 2005 (official source, opens in a new tab)
Applies to every unit and to the common parts. A shopping centre needs a landlord strategy that tenant risk assessments can refer to.

Common questions

Fire strategy questions on retail and leisure buildings, answered.

Cannot see your question? Get in touch and we will answer it directly.

All fire strategy questions

Sometimes, with an engineered case. More often sprinklers unlock the compartment size and the travel distances the layout needs and are the more economical answer. We tell you which applies to your building.

Other sectors

All sectors

Fire strategy for retail and leisure buildings

Tell us about the building

Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK

Request a quote

Same-day reply