Skip to content

Purpose built and converted

Student accommodation combines high occupancy, sleeping risk, cluster flat layouts and a population that changes every year. The strategy has to work for the building and for a management team briefing new residents every September.

Reply
Same-day reply
Fee
Fixed, agreed before we start
Written to
BS 9991:2024, Approved Document B Volume 1, Building Safety Act 2022
Signed off by
A Chartered Engineer (CEng)
Scroll

What makes this sector different

What a fire strategy for student accommodation has to answer.

01

Cluster flats and studios

Compartmentation at the cluster or the room and what that means for the alarm and the evacuation strategy.

02

Simultaneous evacuation

Most student schemes evacuate simultaneously. Exit capacity and assembly have to be designed for it.

03

Higher-risk buildings

Taller schemes are higher-risk buildings and student accommodation counts as residential for the gateway test.

04

Kitchens and false alarms

Detection design that protects sleeping students without training them to ignore the alarm.

Evacuation strategy

How evacuation works in student accommodation

Student accommodation normally evacuates simultaneously. The building is managed, residents are unfamiliar with it at the start of each year and a cluster of bedrooms shares one kitchen. When the alarm sounds everyone leaves and assembles outside. Stairs and exits are sized for the whole building leaving at once.

The alarm design matters as much as the escape routes. Detection in bedrooms and cluster kitchens is often arranged to give a local warning first, with a short investigation period before the whole building sounds. That cuts false alarms from cooking and showers without delaying a real evacuation. The strategy sets out the cause and effect in full, which tells the operator exactly what the system will do.

Our approach

How we write a fire strategy for student accommodation.

We produce strategies for new schemes from planning through Gateway 3 and retrospective strategies for existing halls. The evacuation strategy, the alarm cause and effect and the management arrangements are written for the operator as well as the approver.

Typical deliverables

  • Fire strategy report and plans
  • Evacuation strategy and alarm cause and effect
  • Gateway submissions where applicable
  • Retrospective strategies for existing halls

Standards and guidance

Fire safety guidance for student accommodation

BS 9991:2024
Used for the design of the residential accommodation, including cluster flats and studio layouts.
Approved Document B Volume 1 (official source, opens in a new tab)
The statutory guidance. Halls arranged as self contained cluster flats are generally designed using its guidance for flats.
Building Safety Act 2022 (official source, opens in a new tab)
Student accommodation counts as residential units for the height test. A scheme of 18 metres or seven storeys goes through the gateways.
Fire Safety Order 2005 (official source, opens in a new tab)
Applies to the whole building in use. The operator is the Responsible Person and needs a fire risk assessment and trained staff.

Common questions

Fire strategy questions on student accommodation, answered.

Cannot see your question? Get in touch and we will answer it directly.

All fire strategy questions

Yes. Purpose built student accommodation contains residential units and a scheme at 18 metres or seven storeys is a higher-risk building for both the gateways and the in-occupation duties.

Guides

Guides for student accommodation.

Other sectors

All sectors

Fire strategy for student accommodation

Tell us about the building

Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK

Request a quote

Same-day reply

Only used to reply to this enquiry.

We reply the same day.