Data halls, battery storage and critical infrastructure

A data centre is a building whose owner cares as much about the servers as the people. The strategy has to deliver life safety to the Building Regulations and sit alongside the business continuity, suppression and insurer requirements the operator brings.

Reply
Same-day reply
Fee
Fixed, agreed before we start
Written to
Approved Document B Volume 2, BS 9999:2017, BS EN 15004 gaseous suppression
Signed off by
A Chartered Engineer (CEng)
Scroll

What makes this sector different

What a fire strategy for data centres and energy storage has to answer.

01

Life safety and asset protection

Two objectives in one strategy, kept clearly apart so each can be tested.

02

Suppression

Gaseous and water mist systems, room integrity and the interface with ventilation and power.

03

Battery energy storage

Lithium ion risk, thermal runaway and the separation, detection and ventilation it needs.

04

Large plant and few people

Low occupancy buildings with long travel through plant that still have to escape.

Evacuation strategy

How evacuation works in a data centre

A data centre has very few people in it and they are trained staff who know the building. Evacuation is simultaneous and simple in principle. The complications are long routes through data halls and plant, security doors that must release on alarm and gaseous suppression that can discharge into occupied rooms.

The strategy sets out how each is handled. Access control has to fail safe without compromising security. Suppression needs a pre discharge warning and a hold off control that lets staff leave before the agent is released. Very early smoke detection gives time to investigate and to shut equipment down in an orderly way before a full evacuation is needed.

Our approach

How we write a fire strategy for data centres and energy storage.

We write data centre and energy storage strategies that are explicit about which measures serve life safety and which serve the asset so Building Control can approve the first and the insurer can assess the second. Lithium ion storage is addressed with current guidance rather than assumed to behave like a plant room.

Typical deliverables

  • Fire strategy report and plans
  • Life safety and asset protection statement
  • Battery storage fire safety strategy
  • Suppression and cause and effect design intent

Standards and guidance

Fire safety guidance for data centres and energy storage

Approved Document B Volume 2 (official source, opens in a new tab)
Sets the life safety baseline for escape, compartmentation and fire service access that every data centre has to meet.
BS 9999:2017
Supports longer travel distances where occupancy is low, staff are trained and detection is enhanced.
BS EN 15004 gaseous suppression
The design standard for gaseous fire extinguishing systems, including safe concentrations for occupied spaces.
BS 7974 for engineered cases
Used where hall sizes, travel distances or battery rooms need an engineered case.

Common questions

Fire strategy questions on data centres and energy storage, answered.

Cannot see your question? Get in touch and we will answer it directly.

All fire strategy questions

Yes. It is a building with occupants and the Building Regulations apply in full. The strategy also provides the basis for the business continuity and insurer discussions that follow.

Guides

Guides for data centres and energy storage.

Other sectors

All sectors

Fire strategy for data centres and energy storage

Tell us about the building

Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK