The process

Seven steps, one engineer who stays with the project and no surprises at Building Control. Here is exactly what happens after you get in touch.

Architectural drawings with drafting pencils and a rule

Step by step

What happens, in order.

The first two steps cost you nothing. From step three the fee is fixed, the programme is agreed and the same engineer carries the strategy through to approval.

What we need from you

  • Current architectural drawings, plans and sections
  • The intended use, occupancy numbers and management arrangements
  • The project programme and the stage you are at
  • Any correspondence already exchanged with Building Control or the fire service
  • For existing buildings, access to survey the as-built condition
  1. 01

    Send us the drawings

    You

    Current general arrangement plans, a description of the building and its use and the stage you are at. CAD, model or PDF, whatever you have.

  2. 02

    We scope and quote

    Free

    We confirm which documents the project needs, the route to compliance we recommend and a fixed fee with a programme. All on the same day.

  3. 03

    Consultation

    A conversation with the design team about the goals, the constraints and the sticking points so the strategy shapes the design rather than fights it.

  4. 04

    Design review and analysis

    Layouts, materials, use and occupancy analysed floor by floor. Where the building needs it, engineered analysis and modelling in-house.

  5. 05

    Draft for comment

    The report and annotated plans issued for the design team to check against the current drawings.

  6. 06

    Issue and approval

    The final strategy issued for submission. We engage with Building Control, the Building Safety Regulator and the fire authority on your behalf and answer their questions.

  7. 07

    Keep it current

    Revisions as the design develops, the as-built version at handover and the Regulation 38 pack and golden thread that follow the building.

Across the RIBA stages

What fire strategy delivers at each stage.

Fire safety is a thread, not a single deliverable. Join at any stage and we pick up the thread from there.

Stage 0 to 1

Strategic definition and preparation

Initial fire safety objectives, site constraints and feasibility input to inform the brief. On a higher-risk scheme, the threshold check for Gateway 1.

Stage 2

Concept design

Concept fire strategy, means of escape, compartmentation approach and fire safety design options. The planning fire statement for Gateway 1 and London Plan D12.

Stage 3

Spatial coordination

Developed fire strategy, updated escape analysis, compartmentation coordination and the design parameters for suppression and detection.

Stage 4

Technical design

Technical fire strategy and specifications, fire strategy plans and the Gateway 2 submission to the Building Safety Regulator. Coordination with structural and services engineers.

Stage 5

Manufacturing and construction

Review of contractor submissions, resolution of fire safety queries and change control on higher-risk buildings.

Stage 6

Handover

As-built fire strategy and plans, the Regulation 38 pack, Gateway 3 completion evidence and the golden thread handed to the Accountable Person.

Stage 7

Use

The strategy becomes the baseline for the fire risk assessment, the safety case and every future change to the building.

Higher-risk

Gateway 1, 2 and 3 slot into Stages 2, 4 and 6.

Gateway support

The standards we work to

Grounded in the recognised UK framework.

Every strategy states which route it takes and why so the approver can follow the reasoning rather than take it on trust.

ADB

Approved Document B

The statutory guidance supporting Part B of the Building Regulations in England. One route to compliance, not the only one.

BS 9999

BS 9999:2017

The risk based code of practice for fire safety in the design, management and use of non residential buildings.

BS 9991

BS 9991:2024

The code of practice for residential buildings. An advisory note developed with the Building Safety Regulator says Gateway 2 applications adopting it should use the 2024 edition from 30th September 2026.

BS 7974

BS 7974 and PD 7974

The framework for applying fire safety engineering principles to building design. The basis of every first principles strategy we write.

BSA

Building Safety Act 2022

The regime for higher-risk buildings. Three gateways, the golden thread, the safety case and the Building Safety Regulator.

FSO

Fire Safety Order 2005

The law for occupied premises. The strategy is the design intent the Responsible Person manages the building against.

Step one

Send us the drawings

Attach what you have or describe the building. We come back the same day with the scope, the route we recommend and a fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK

Request a quote

Same-day reply

Only used to reply to this enquiry.

We reply the same day.