Schools, colleges and universities

Schools fill up at nine and empty at half past three. The strategy has to move large numbers of children quickly, protect the building from the arson risk schools face and meet the Department for Education's expectations as well as the Building Regulations.

Reply
Same-day reply
Fee
Fixed, agreed before we start
Written to
Approved Document B Volume 2, BB 100 Design for fire safety in schools, BS 9999:2017
Signed off by
A Chartered Engineer (CEng)
Scroll

What makes this sector different

What a fire strategy for schools has to answer.

01

BB 100

The design guide for fire safety in schools, including its approach to sprinklers and property protection.

02

Occupancy and exits

Exit capacity and assembly for whole school evacuation, including pupils who need assistance.

03

Educational accommodation at planning

Tall buildings with educational accommodation trigger the Gateway 1 fire statement.

04

Expansion and extension

Growing schools add blocks and alter escape routes. Each change has to be reconciled with the strategy.

Evacuation strategy

How evacuation works in a school

Schools evacuate simultaneously. The whole school leaves by class and assembles at a known point for a roll call. Children are supervised and that makes evacuation orderly. Large numbers still have to leave rooms, corridors and stairs at the same moment. Exit widths and stair capacity are sized for the full roll, including halls and dining spaces at their busiest.

Fires in schools are often started deliberately and often when the building is empty. Life safety is rarely the only concern. BB 100 asks designers to consider protecting the building itself through sprinklers, compartmentation and security. A school that burns down disrupts education for years. The strategy records what has been provided for life safety and what for property protection.

Our approach

How we write a fire strategy for schools.

We produce school and college strategies to Approved Document B and BB 100 and university strategies that handle the mix of teaching, laboratory and residential uses. We set out the evacuation strategy for the whole site so the school can run it.

Typical deliverables

  • Fire strategy report and plans
  • Whole site evacuation strategy
  • Sprinkler and property protection advice
  • Gateway 1 fire statements for tall educational buildings

Standards and guidance

Fire safety guidance for schools

Approved Document B Volume 2 (official source, opens in a new tab)
The statutory guidance. It refers designers of schools to BB 100.
BB 100 Design for fire safety in schools (official source, opens in a new tab)
The Department for Education's design guide. It expects a risk assessment on whether sprinklers should be fitted.
BS 9999:2017
An alternative route often used for colleges and universities with large or unusual teaching spaces.
Fire Safety Order 2005 (official source, opens in a new tab)
Applies to every school in use. The governing body or trust is normally the Responsible Person.

Common questions

Fire strategy questions on schools, answered.

Cannot see your question? Get in touch and we will answer it directly.

All fire strategy questions

There is no blanket legal requirement in England but BB 100 expects a risk assessment to inform the decision and many funders and local authorities expect them. We set out the case either way in the strategy.

Guides

Guides for schools.

Other sectors

All sectors

Fire strategy for schools

Tell us about the building

Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK