Skip to content

North Wales, Mid and West Wales and South Wales

Wales writes its own building regulations guidance, applies its own test for higher-risk buildings and has required sprinklers in new homes since 1st January 2016. We write fire strategies for buildings across Wales, from converted homes and care homes to tall blocks that the council now approves under the Welsh procedures.

Reply
Same-day reply
Fee
Fixed, agreed before we start
Signed off by
A Chartered Engineer (CEng)
Coverage
In-house engineering, UK wide
Scroll

Overview

Fire strategy across Wales

Building regulations for Wales are made by the Welsh Ministers, who also publish Approved Document B for Wales in two volumes. Both volumes rest on the 2006 edition with amendments up to 2020 and an amendment slip that took effect on 20th December 2025. They are not the English 2019 document and their paragraph numbers differ. Every new or converted house and flat in Wales has needed an automatic fire suppression system since 1st January 2016.

A Welsh higher-risk building is at least 18 metres high or has at least 7 storeys and contains at least one residential unit, a hospital with overnight beds, a care home or a children's home. Hotels and a few other excluded buildings fall outside it. The council is the building control authority for that work and registered building control approvers cannot take it on. Since 1st July 2026 higher-risk building work has needed building control approval under the Welsh procedures, unless full plans or an initial notice went in before that date. The application includes a fire and emergency file that Welsh Government guidance says is often known as a fire strategy. The council must consult the fire and rescue authority on the application and cannot decide it before the end of 15 working days.

Planning follows Future Wales: the National Plan 2040, Planning Policy Wales Edition 12 and each council's Local Development Plan, with four Corporate Joint Committees given the job of preparing strategic development plans. Welsh applications carry no planning fire statement. Instead the fire and rescue authority has been a statutory consultee on larger housing and commercial schemes since 2022, with its responses aimed at appliance access and water for firefighting. The Building Safety (Wales) Act 2026 received Royal Assent on 27th April 2026 for occupied buildings with two or more residential units, although no order bringing its main duties into force had been found by 15th November 2026.

Who decides

Who approves a fire strategy in Wales

Fire and rescue
Mid and West Wales Fire and Rescue Service (official source, opens in a new tab)
Building control bodies send consultations to it by email only. It replies within the 15 day statutory period.
Fire and rescue
North Wales Fire and Rescue Service (official source, opens in a new tab)
Business fire safety teams work from Colwyn Bay, Wrexham and Caernarfon. We found no separate building regulations page on its site.
Fire and rescue
South Wales Fire and Rescue Service (official source, opens in a new tab)
Its protection pages cover fire alarms, licensing, building regulations and the primary authority scheme.
Higher-risk buildings
Welsh Government (official source, opens in a new tab)
Guidance published on 18th June 2026 confirming that councils oversee and approve higher-risk building work in Wales.

Local issues

What a Welsh fire strategy has to deal with.

01

One flat is enough

In Wales a building of at least 18 metres or 7 storeys is higher-risk once it holds a single residential unit. A children's home counts too. England's test needs at least two residential units. A tall office block with one flat at the top therefore goes through the full Welsh higher-risk procedure.

02

The council approves tall buildings

Higher-risk building work in Wales is approved by the council, not by the Building Safety Regulator. An application for a new higher-risk building must be decided within 12 weeks unless a longer period is agreed in writing. Its fire and emergency file must include a plan of the fire service's access and water supply needs. That file goes to the fire and rescue authority as part of the statutory consultation.

03

Sprinklers in every new home

New and converted houses and flats have needed automatic fire suppression since 1st January 2016. Care homes and most rooms for residential purposes have needed it since 30th April 2014, with children's care homes added from 17th December 2024. Hotels and hostels sit outside that rule. Listed buildings and conservation areas are exempt only where a system would unacceptably alter their character or appearance.

04

A wider combustible materials ban

SI 2025/704 came into force on 20th December 2025 and extended the combustible materials ban to hotels, hostels and boarding houses. It also banned relevant metal composite material in the external walls of buildings of any height. The height at which a change of use of a whole building triggers the external fire spread rule fell from 15 metres to 11 metres at the same time.

Building types

The building types we see across Wales

Common questions

Fire strategy questions in Wales, answered.

Cannot see your question? Get in touch and we will answer it directly.

All fire strategy questions

The regulator does not approve them, since the council is the building control authority for higher-risk buildings in Wales. Its Welsh role is registering building control approvers on behalf of the Welsh Ministers.

Guides

Guides worth reading first.

Other locations

All locations

Fire strategy in Wales

Tell us about the building

Send us the drawings, the building type and the stage you are at. We reply the same day with a clear scope, programme and fixed fee.

  • 01Written in-house by the engineer who will defend it to the approver
  • 02Approved Document B, BS 9999, BS 9991 and BS 7974
  • 03Building Control and fire authority engagement handled for you
  • 04Projects of every size, across the UK

Request a quote

Same-day reply

Only used to reply to this enquiry.

We reply the same day.