Who are the Accountable Person and Principal Accountable Person?
Under section 72 of the Building Safety Act 2022 (opens in a new tab) an Accountable Person (AP) is a person who holds a legal estate in possession in any part of the common parts of a higher-risk building. A person without a legal estate who is under a relevant repairing obligation for any part of the common parts is also an AP. On commonhold land the commonhold association is the AP. Common parts include the structure and exterior of the building and parts provided for the residents of more than one unit.
Under section 73 (opens in a new tab) a building with one AP has that person as its Principal Accountable Person (PAP). Where there are several, the PAP is the AP who holds the legal estate in the relevant parts of the structure and exterior or has the repairing obligation for them.
The Building Safety Regulator's (BSR) guidance for accountable persons (opens in a new tab) gives common parts such as corridors, lobbies and staircases as examples. It says each building must have one clearly identifiable AP, known as the PAP.
An AP can be a freeholder or estate owner, a landlord, a management company, a resident management company, a right to manage company or a commonhold association. BSR says the PAP is usually an organisation such as a commonhold association, local authority or social housing provider. An individual can also be the PAP.
A management company that maintains the building under a contract is not an AP, while one that a lease requires to repair or maintain the common parts is the AP for those parts. The duties apply once the building is occupied, which section 71 (opens in a new tab) defines as having residents of more than one residential unit. Our building safety case reports service supports APs with these duties.
What APs and the PAP must do
BSR's guidance splits the duties between every AP and the PAP, which is itself an AP and carries both sets.
| Duty | Who |
|---|---|
| Assess and manage the risks from structural failure or the spread of fire in their parts | Each AP |
| Report safety occurrences | Each AP and the PAP |
| Carry out resident engagement strategy duties | Each AP |
| Keep the golden thread information about the building | Each AP |
| Provide building information to relevant individuals and organisations | Each AP and the PAP |
| Register the building and submit structure and fire safety information | The PAP |
| Prepare and update the safety case report | The PAP |
| Operate a mandatory occurrence reporting system | The PAP |
| Operate a complaints system | The PAP |
| Display required information clearly within the building | The PAP |
| Prepare and update a resident engagement strategy | The PAP |
| Apply for a building assessment certificate when told | The PAP |
BSR says APs and the PAP cannot delegate their legal obligations to others. A managing agent can carry out duties but the accountability and the liability for the building's safety remain with the APs and the PAP. An organisation PAP can name a person or a third party as single point of contact for BSR with written consent. That does not make them the PAP.
Where there is one AP, it is responsible for the common parts, residential units, commonhold units, balconies and any other part not covered by the Fire Safety Order. Where there are several, each covers the common parts and balconies it owns or must repair and units let other than on a long lease. BSR says they must work together and share safety information. For a unit on a long lease of more than 21 years under section 115 (opens in a new tab), the AP must prevent risk in it that could affect common parts and other units.
Where the AP or PAP is not also the Responsible Person under the Regulatory Reform (Fire Safety) Order 2005, building safety information must be shared between them. APs and PAPs must either have the relevant competence or appoint someone with it under regulation 4 of SI 2023/907 (opens in a new tab). BSR points to PAS 8673 as a benchmark but says compliance with it or any other standard does not guarantee meeting all legal obligations.
If it is unclear who is an AP or the PAP, an owner, a person with a repairing obligation or BSR can apply to the First-tier Tribunal for a decision.
What the golden thread is
BSR's golden thread guidance (opens in a new tab) says the information about a building is sometimes known as the golden thread. It applies in England to clients, principal designers and principal contractors on higher-risk building projects and to APs and PAPs of high-rise residential buildings.
In occupation the duty is in section 88 of the Act (opens in a new tab), fully in force since 16th January 2024. An AP must keep prescribed information and copies of prescribed documents in accordance with prescribed standards and keep the information up to date so far as possible. Where it does not hold them it must obtain them unless that is not practicable.
The Higher-Risk Buildings (Keeping and Provision of Information etc.) (England) Regulations 2024 (opens in a new tab), SI 2024/41, call these prescribed items together the golden thread information. They came into force on 16th January 2024 and apply to England only.
During design and construction the duty sits with the client under regulation 31 of SI 2023/909 (opens in a new tab), in force since 1st October 2023. The client must create and maintain an electronic facility to hold the golden thread information, with access for designers and contractors. Gaps at handover are hard to fill once the design team has gone.
The golden thread during design and construction
BSR's guidance tells the client to keep information that describes the building and shows how it complies with building regulations, in a system that should have version control. The principal designer must capture and keep all of the design information up to date. The principal contractor must use the record-keeping system the client provides.
Before construction starts the facility must hold a copy of the fire statement and the approved plans and documents, together with all the evidence recorded to show compliance. As work proceeds it takes the agreed documents, change control records, notices of any new principal designer or principal contractor, mandatory occurrence reports and the proposed completion certificate application.
Regulation 31(2) sets standards close to those for occupation described below. The information must be electronic and transferable without loss, accurate and up to date, intelligible, secure and changed only under procedures that record who made the change and when. It must also be available on request to the principal designer or principal contractor and use consistent language, terminology and definitions as far as is reasonably practicable.
At completion regulation 38 (opens in a new tab) requires the client to give the specified golden thread information to the accountable person and any responsible person. That is a copy of the completion certificate application and its documents. It must be given no later than the date the work is completed and must keep the filing structure in which it was held. The recipient must acknowledge they can access it and that it is sufficient to understand, operate and maintain the building and its fire safety systems.
The fire safety information required by Regulation 38 goes over at the same time. BSR advises maintaining a clear and up-to-date golden thread of fire and structural safety information throughout the project. Our guide to Gateway 3 covers the completion evidence.
What APs must keep once the building is occupied
Schedule 1 of SI 2024/41 (opens in a new tab) lists the golden thread information. Each AP keeps the items relating to its part of the building and some items fall to the PAP alone. The main information items are these.
- Fire safety information for scheme work.
- Up-to-date registration information and the key building information given to BSR, kept by the PAP only.
- A list of each fire safety management measure and a record of where each is located.
- The evacuation strategy and evacuation information for the AP's part, kept for the whole building by the PAP.
- Information under regulation 4 of the Fire Safety (England) Regulations 2022.
- A list of each structural safety measure in the building.
- Planned maintenance and repair schedules and the most recent inspection report for building safety risks.
- Building design information, including any design code and any British or International building standard applied to and complied with in its construction.
- Mandatory occurrence reports and the steps taken, where no more than 7 years have passed.
- Summaries of relevant complaints and their outcomes for 7 years.
The documents include the completion certificate application, its documents and the certificate, competent person scheme certificates, the most recent fire risk assessment documents, the external wall record and floor plans including the single page building plan. Structural risk assessments, building safety risk assessment reports, the safety case report, maintenance and repair records and plans of the building as currently constructed and as first constructed are also on the list. Several records, such as maintenance records and complaint logs, are limited to the last 7 years and contravention notices to the last 5.
BSR's guidance gives a shorter list that includes the building's health and safety file, safety case report, residents' engagement strategy and mandatory occurrence reporting system. The health and safety file is named in BSR's guidance but not in the regulations. BSR also says APs must be able to understand the fire strategy for the parts of the building they are responsible for.
Our guides to the building safety case and the safety case report cover how that report is prepared and what it contains.
The standards the information must meet
Regulation 7 of the Higher-Risk Buildings (Management of Safety Risks etc) (England) Regulations 2023 (opens in a new tab), in force since 16th January 2024, sets the standards for the information APs keep. Documents must meet similar standards.
- Kept in an electronic format that can be transferred to other people without the data being lost or corrupted.
- Kept accurate.
- Intelligible to the intended readers, with any key needed to understand the data provided with it.
- Accessible as soon as reasonably practicable in response to a request.
- Secure from unauthorised access.
- Changed only under procedures that record the person who made the change and the date.
BSR's guidance adds principles. Information should be kept digitally, secure, available when someone needs it and presented in a way someone can use. It calls the golden thread a building's single source of truth and says the information should be written in plain English and comply with the General Data Protection Regulation.
Passing the information on
When an AP changes, section 90 (opens in a new tab) requires the outgoing AP to give the incoming AP the prescribed information and documents. Regulation 13 of SI 2024/41 (opens in a new tab) sets these as all the golden thread information the outgoing AP was required to keep. The outgoing AP must also notify BSR. Failing without reasonable excuse to pass the information on or to notify BSR is an offence. On indictment it carries up to two years' imprisonment or a fine, with a further daily fine on summary conviction while the default continues.
Regulation 9 of SI 2023/907 (opens in a new tab) says the information must be given as soon as reasonably practicable, electronically without loss or corruption of data and in intelligible form. BSR must be told who the outgoing person is, the building and its registration number, the date they ceased to be an AP and details of the new person. An AP must also tell BSR when an administrator, receiver, liquidator or similar office holder is appointed.
Under regulation 12 of SI 2024/41 (opens in a new tab) the PAP must give the local fire and rescue authority the key building information, the evacuation information for the whole building, any building assessment certificate refusal notice and the safety case report. Each AP must give its own items, such as evacuation information, external wall records, floor plans and plans of current construction. Any golden thread item must be supplied on written request.
A client planning work in an occupied higher-risk building who gives the AP written notice must be given relevant information such as structural safety measures, fire risk assessment documents and plans of current construction. Registration and key building information are covered in our guide to what is a higher-risk building.
What residents receive and what they must do
Each AP must give the information in Schedule 2 of SI 2024/41 (opens in a new tab) to each person aged 16 or over who lives in its part of the building. The duty does not apply to a resident the AP is unaware of after taking all reasonable steps. It must also take all reasonable steps to give it to owners. Under regulation 8 of SI 2023/907 (opens in a new tab) it goes out as soon as reasonably practicable after occupation or a change of AP, after a new resident moves in and when information becomes out of date.
- A summary of the most recent fire risk assessment, including an evaluation of the level of risk to residents.
- A summary of the safety case report, including the steps taken or planned and how effectively identified risks are being managed.
- How residents can prevent and reduce risks in their unit, how and to whom to report a building safety risk and their own duties under section 95.
- Where fire escape routes, fire doors and fire and smoke control equipment are, instructions for equipment intended for residents and evacuation information.
- The roles and contact details of BSR, the PAP, the relevant AP, any Responsible Person and any single point of contact.
- The latest residents' engagement strategy, what residents can request, the complaints procedure and how to complain to BSR.
The information must be in writing and understandable, with explanations of technical language or plain English summaries. How to report a building safety risk, how to complain and the contact details of the PAP, other APs, any Responsible Person and the single point of contact must also be displayed in the common parts.
Under section 92 (opens in a new tab) a resident aged 16 or over or an owner can request prescribed information. The AP must provide it as soon as reasonably practicable in writing and in an understandable form, subject to exceptions for security, commercial sensitivity and personal data.
Under section 93 the PAP must run a system for investigating relevant complaints about a building safety risk or an AP's duties. Any person is able to make a relevant complaint. The PAP must also prepare a residents' engagement strategy (opens in a new tab), review it at least every two years and consult on it for no less than 3 weeks.
Residents have duties too. Under section 95 (opens in a new tab) residents aged 16 or over and owners must not act in a way that creates a significant risk of a building safety risk materialising or interfere with a relevant safety item. They must also comply with an AP's reasonable request for information needed for its risk duties.
Where a resident appears to be breaching these duties, an AP can issue a plain English contravention notice with a timescale and a county court order can follow.
BSR's current approach, Wales and Scotland
On 9th July 2026 BSR announced a more proportionate and targeted approach (opens in a new tab) to building assessments. It will only call in new applications when necessary until improved processes are agreed and will give volunteer-run resident management companies more time. It also said PAPs must not wait for any future assessments before preparing safety case reports, a duty enforceable since January 2024.
These duties apply in England only. The Building Safety (Wales) Act 2026 sets up a Welsh occupation regime with accountable persons, a PAP and a local authority building safety authority for buildings of at least 11 metres or 5 storeys. Many of its duties await commencement. The Welsh design and construction procedures in force from 1st July 2026 include a golden thread Part. Our guide to higher-risk buildings in Wales covers that regime.
Scotland has no accountable person or golden thread regime. Parts 2 to 5 of the Building Safety Act 2022 extend to England and Wales only. Our Scotland page covers projects there.
Where the record has gaps, our building safety case reports service starts from the evidence you already hold. For new buildings our Regulation 38 fire safety information service prepares the fire safety information handed over at completion.
Sources
This guide was written from these official sources. Check the current version before relying on any figure.
- Building Safety Act 2022, section 72 (official source, opens in a new tab)
- Building Safety Act 2022, section 73 (official source, opens in a new tab)
- Building Safety Act 2022, section 88 (official source, opens in a new tab)
- Building Safety Act 2022, section 90 (official source, opens in a new tab)
- Building Safety Act 2022, section 95 (official source, opens in a new tab)
- Higher-Risk Buildings (Keeping and Provision of Information etc.) (England) Regulations 2024, Schedule 1 (official source, opens in a new tab)
- Higher-Risk Buildings (Keeping and Provision of Information etc.) (England) Regulations 2024, Schedule 2 (official source, opens in a new tab)
- Higher-Risk Buildings (Management of Safety Risks etc) (England) Regulations 2023, regulation 7 (official source, opens in a new tab)
- Building (Higher-Risk Buildings Procedures) (England) Regulations 2023, regulation 31 (official source, opens in a new tab)
- Building (Higher-Risk Buildings Procedures) (England) Regulations 2023, regulation 38 (official source, opens in a new tab)
- Safety in High-Rise Residential Buildings: Accountable Persons (BSR) (official source, opens in a new tab)
- Keeping Information About a Higher-Risk Building: The Golden Thread (BSR) (official source, opens in a new tab)
- Preparing a Resident Engagement Strategy (BSR) (official source, opens in a new tab)